@@ -1,3 +1,19 @@
# WashData - Home Assistant integration for appliance cycle monitoring via smart plugs.
# Copyright (C) 2026 Lukas Bandura
# SPDX-License-Identifier: AGPL-3.0-or-later
#
# This program is free software: you can redistribute it and/or modify
# it under the terms of the GNU Affero General Public License as published
# by the Free Software Foundation, either version 3 of the License, or
# (at your option) any later version.
#
# This program is distributed in the hope that it will be useful,
# but WITHOUT ANY WARRANTY; without even the implied warranty of
# MERCHANTABILITY or FITNESS FOR A PARTICULAR PURPOSE. See the
# GNU Affero General Public License for more details.
#
# You should have received a copy of the GNU Affero General Public License
# along with this program. If not, see <https://www.gnu.org/licenses/>.
"""Feature extraction logic for WashData.
Constraint: NumPy only.
@@ -7,25 +23,9 @@ Constraint: All computations must be dt-aware.
from dataclasses import dataclass
import numpy as np
@dataclass
class PowerEvent:
"""Represent a detected power change event."""
timestamp: float
magnitude: float # Absolute change in Watts
rate: float # Slope W/s
direction: str # "rising" or "falling"
from .signal_processing import energy_gap_threshold_s, integrate_wh
@dataclass
class CyclePhase:
"""Represent a distinct phase within a cycle."""
start_ts: float
end_ts: float
label: str # HEATER, MOTOR, IDLE, etc.
avg_power: float
@dataclass
@@ -35,7 +35,7 @@ class CycleSignature:
duration: float
total_energy: float
max_power: float
event_density: float # Events per minute
event_density: float # Deprecated/reserved: always 0.0 (event detector removed); kept for signature back-compat
time_to_first_high: float # Seconds to first HEATER/HIGH phase
high_phase_ratio: float # Duration of high phases / total duration
# Distributions (quantiles of power)
@@ -46,144 +46,16 @@ class CycleSignature:
p95: float
def detect_events(
timestamps: np.ndarray,
power: np.ndarray,
idle_mad: float,
min_event_watts: float = 50.0,
) -> list[PowerEvent]:
"""Detect significant power events using dp/dt.
Args:
timestamps: Time array (seconds).
power: Power array (Watts).
idle_mad: Media Absolute Deviation of idle baseline (noise floor).
min_event_watts: Absolute floor for an event to be considered.
"""
if len(power) < 2:
return []
dt = np.diff(timestamps)
dp = np.diff(power)
# Avoid div by zero
valid = dt > 0.1
rate = np.zeros_like(dp)
rate[valid] = dp[valid] / dt[valid]
# Adaptive threshold
# 3-sigma equivalent: 3 * 1.4826 * MAD ~= 4.5 * MAD
# But for dp/dt, noise scales differently.
# Let's use absolute threshold + noise factor.
noise_allowance = max(10.0, 5.0 * idle_mad)
events: list[PowerEvent] = []
for i, r in enumerate(rate):
if not valid[i]:
continue
mag = abs(dp[i])
# Criteria: Significant rate AND significant magnitude
# We want to ignore small jitter even if rate is high (dt small)
if mag > min_event_watts and abs(r) > noise_allowance: # Rate threshold W/s
# Basic check: if dt is tiny (1s) and power jump is 50W, rate is 50 W/s.
# If dt is 10s and power jump is 50W, rate is 5 W/s.
# Real heater on: 2000W in ~2s => 1000 W/s.
# Motor tumble: 200W in 1s => 200 W/s.
direction = "rising" if r > 0 else "falling"
events.append(
PowerEvent(
timestamp=timestamps[i], magnitude=mag, rate=r, direction=direction
)
)
return events
def segment_phases(timestamps: np.ndarray, power: np.ndarray) -> list[CyclePhase]:
"""Segment cycle into phases using quantile-based thresholds.
Labels:
- IDLE: < p10 (or min threshold)
- MOTOR: p25 - p75 approx
- HEATER/HIGH: > p90
Refined logic:
1. Calculate cycle quantiles.
2. Define levels: LOW, MED, HIGH.
3. Run-length encoding or simple state machine.
"""
if len(power) < 10:
return []
# Quantiles
q_low = np.percentile(power, 25)
q_high = np.percentile(power, 90)
# Enforce device minimums to avoid "High" label on a 5W phone charger cycle
min_high = 500.0
min_motor = 50.0
# Adjust thresholds
thresh_high = max(q_high, min_high)
thresh_med = max(q_low, min_motor)
labels: list[str] = []
for p in power:
if p >= thresh_high:
labels.append("HEATER")
elif p >= thresh_med:
labels.append("MOTOR")
else:
labels.append("IDLE")
# Merge consecutive
phases: list[CyclePhase] = []
if not labels:
return []
current_label: str = labels[0]
start_idx = 0
for i in range(1, len(labels)):
if labels[i] != current_label:
# End current phase
phases.append(
CyclePhase(
start_ts=timestamps[start_idx],
end_ts=timestamps[i - 1],
label=current_label,
avg_power=float(np.mean(power[start_idx:i])),
)
)
current_label = labels[i]
start_idx = i
# Last one
phases.append(
CyclePhase(
start_ts=timestamps[start_idx],
end_ts=timestamps[-1],
label=current_label,
avg_power=float(np.mean(power[start_idx:])),
)
)
return phases
def compute_signature(
timestamps: np.ndarray, power: np.ndarray, events: list[PowerEvent] | None = None
timestamps: np.ndarray, power: np.ndarray
) -> CycleSignature:
"""Compute compact signature for candidate rejection/matching.
Args:
timestamps: Timestamps (seconds)
power: Power (Watts)
events: Pre-computed events (optional)
"""
if len(power) == 0:
# Return empty/zero signature
@@ -191,15 +63,10 @@ def compute_signature(
duration = timestamps[-1] - timestamps[0]
# Energy approx
dt = np.diff(timestamps)
# Simple rectangular for speed here, or integrate_wh
if len(dt) > 0:
p_avg = (power[:-1] + power[1:]) / 2
total_energy = np.sum(p_avg * (dt / 3600.0))
else:
total_energy = 0.0
# Energy (trapezoidal Wh) via the shared integrator - single source of truth.
total_energy = integrate_wh(timestamps, power, max_gap_s=energy_gap_threshold_s(timestamps))
dt = np.diff(timestamps) # sample intervals (s), reused by the high-phase ratio
max_p = np.max(power)
# Quantiles
@@ -219,20 +86,20 @@ def compute_signature(
# Time in high / total time
# Check dt where high_mask holds
if len(dt) > 0:
# Align mask with intervals
# mask[i] corresponds to interval i? roughly
high_dur = np.sum(dt[high_mask[:-1]])
# Align mask with intervals; mask[i] corresponds to interval i.
# Exclude sensor-outage gaps: a long gap after a high-power sample is a data
# dropout, not high-phase time, so cap those intervals to 0 (mirrors the energy
# integrator's gap handling via energy_gap_threshold_s).
max_gap = energy_gap_threshold_s(timestamps)
capped_dt = np.where(dt > max_gap, 0.0, dt)
high_dur = np.sum(capped_dt[high_mask[:-1]])
high_phase_ratio = high_dur / duration if duration > 0 else 0
else:
high_phase_ratio = 0.0
# Event density
if not events:
# Compute locally if needed, but ideally passed in
pass
event_count = len(events) if events else 0
event_density = (event_count / (duration / 60.0)) if duration > 60 else 0
# Event density: always 0 now that the event detector is gone; retained as a
# signature field for backward compatibility with stored signatures.
event_density = 0.0
return CycleSignature(