Added VT Thermometer to HACS
This commit is contained in:
@@ -0,0 +1,154 @@
|
||||
# pylint: disable=line-too-long
|
||||
""" This file implements the Open Window by temperature algorithm
|
||||
This algo works the following way:
|
||||
- each time a new temperature is measured
|
||||
- calculate the slope of the temperature curve. For this we calculate the slope(t) = 1/2 slope(t-1) + 1/2 * dTemp / dt
|
||||
- if the slope is lower than a threshold the window opens alert is notified
|
||||
- if the slope regain positive the end of the window open alert is notified
|
||||
"""
|
||||
|
||||
import logging
|
||||
from vtherm_api.log_collector import get_vtherm_logger
|
||||
from datetime import datetime
|
||||
|
||||
_LOGGER = get_vtherm_logger(__name__)
|
||||
|
||||
# To filter bad values
|
||||
MIN_DELTA_T_SEC = 0 # two temp mesure should be > 0 sec
|
||||
MAX_SLOPE_VALUE = (
|
||||
120 # slope cannot be > 2°/min or < -2°/min -> else this is an aberrant point
|
||||
)
|
||||
|
||||
MAX_DURATION_MIN = 30 # a fake data point is added in the cycle if last measurement was older than 30 min
|
||||
|
||||
MIN_NB_POINT = 4 # do not calculate slope until we have enough point
|
||||
|
||||
|
||||
class WindowOpenDetectionAlgorithm:
|
||||
"""The class that implements the algorithm listed above"""
|
||||
|
||||
def __init__(self, alert_threshold, end_alert_threshold, vtherm=None) -> None:
|
||||
"""Initalize a new algorithm with the both threshold"""
|
||||
self._alert_threshold: float = alert_threshold
|
||||
self._end_alert_threshold: float = end_alert_threshold
|
||||
self._last_slope: float | None = None
|
||||
self._last_datetime: datetime = None
|
||||
self._last_temperature: float | None = None
|
||||
self._nb_point: int = 0
|
||||
self._vtherm = vtherm
|
||||
|
||||
def check_age_last_measurement(self, temperature, datetime_now) -> float:
|
||||
""" " Check if last measurement is old and add
|
||||
a fake measurement point if this is the case
|
||||
"""
|
||||
if self._last_datetime is None:
|
||||
return self.add_temp_measurement(temperature, datetime_now)
|
||||
|
||||
delta_t_sec = float((datetime_now - self._last_datetime).total_seconds()) / 60.0
|
||||
if delta_t_sec >= MAX_DURATION_MIN:
|
||||
return self.add_temp_measurement(temperature, datetime_now, False)
|
||||
else:
|
||||
# do nothing
|
||||
return self._last_slope
|
||||
|
||||
def add_temp_measurement(
|
||||
self, temperature: float, datetime_measure: datetime, store_date: bool = True
|
||||
) -> float:
|
||||
"""Add a new temperature measurement
|
||||
returns the last slope
|
||||
"""
|
||||
if self._last_datetime is None or self._last_temperature is None:
|
||||
_LOGGER.debug("%s - First initialisation", self)
|
||||
self._last_datetime = datetime_measure
|
||||
self._last_temperature = temperature
|
||||
self._nb_point = self._nb_point + 1
|
||||
return None
|
||||
|
||||
_LOGGER.debug(
|
||||
"%s - We are already initialized slope=%s last_temp=%0.2f",
|
||||
self,
|
||||
self._last_slope,
|
||||
self._last_temperature,
|
||||
)
|
||||
lspe = self._last_slope
|
||||
|
||||
delta_t_sec = float((datetime_measure - self._last_datetime).total_seconds())
|
||||
delta_t = delta_t_sec / 60.0
|
||||
if delta_t_sec <= MIN_DELTA_T_SEC:
|
||||
_LOGGER.debug(
|
||||
"%s - Delta t is %d < %d which should be not possible. We don't consider this value",
|
||||
self,
|
||||
delta_t_sec,
|
||||
MIN_DELTA_T_SEC,
|
||||
)
|
||||
return lspe
|
||||
|
||||
delta_t_hour = delta_t / 60.0
|
||||
|
||||
delta_temp = float(temperature - self._last_temperature)
|
||||
new_slope = delta_temp / delta_t_hour
|
||||
if new_slope > MAX_SLOPE_VALUE or new_slope < -MAX_SLOPE_VALUE:
|
||||
_LOGGER.debug(
|
||||
"%s - New_slope is abs(%.2f) > %.2f which should be not possible. We don't consider this value",
|
||||
self,
|
||||
new_slope,
|
||||
MAX_SLOPE_VALUE,
|
||||
)
|
||||
return lspe
|
||||
|
||||
if self._last_slope is None:
|
||||
self._last_slope = round(new_slope, 2)
|
||||
else:
|
||||
self._last_slope = round((0.2 * self._last_slope) + (0.8 * new_slope), 2)
|
||||
|
||||
# if we are in cycle check and so adding a fake datapoint, we don't store the event datetime
|
||||
# so that, when we will receive a real temperature point we will not calculate a wrong slope
|
||||
if store_date:
|
||||
self._last_datetime = datetime_measure
|
||||
|
||||
self._last_temperature = temperature
|
||||
|
||||
self._nb_point = self._nb_point + 1
|
||||
_LOGGER.debug(
|
||||
"%s - delta_t=%.3f delta_temp=%.3f new_slope=%.3f last_slope=%s slope=%.3f nb_point=%s",
|
||||
self,
|
||||
delta_t,
|
||||
delta_temp,
|
||||
new_slope,
|
||||
lspe,
|
||||
self._last_slope,
|
||||
self._nb_point,
|
||||
)
|
||||
|
||||
return self._last_slope
|
||||
|
||||
def is_window_open_detected(self) -> bool:
|
||||
"""True if the last calculated slope is under (because negative value) the _alert_threshold"""
|
||||
if self._alert_threshold is None:
|
||||
return False
|
||||
|
||||
if self._nb_point < MIN_NB_POINT or self._last_slope is None:
|
||||
return False
|
||||
|
||||
return self._last_slope < -self._alert_threshold
|
||||
|
||||
def is_window_close_detected(self) -> bool:
|
||||
"""True if the last calculated slope is above (cause negative) the _end_alert_threshold"""
|
||||
if self._end_alert_threshold is None:
|
||||
return False
|
||||
|
||||
if self._nb_point < MIN_NB_POINT or self._last_slope is None:
|
||||
return False
|
||||
|
||||
return self._last_slope >= self._end_alert_threshold
|
||||
|
||||
@property
|
||||
def last_slope(self) -> float:
|
||||
"""Return the last calculated slope"""
|
||||
return self._last_slope
|
||||
|
||||
def __str__(self) -> str:
|
||||
if self._vtherm and hasattr(self._vtherm, "name"):
|
||||
return f"{self._vtherm.name}-WindowOpenDetectionAlgorithm"
|
||||
else:
|
||||
return f"UnknownVTherm-WindowOpenDetectionAlgorithm"
|
||||
Reference in New Issue