112 files
This commit is contained in:
@@ -794,12 +794,28 @@ def projected_energy(
|
||||
price: float | None,
|
||||
end_expectation_fn: EndExpFn,
|
||||
logger: logging.Logger | None = None,
|
||||
cost_so_far: float | None = None,
|
||||
cost_so_far_wh: float | None = None,
|
||||
) -> tuple[float | None, float | None]:
|
||||
"""Project total energy (Wh) and cost for the running cycle.
|
||||
|
||||
Prefers the on-device ``total_energy`` regressor; otherwise falls back to
|
||||
``energy_so_far / progress_fraction``. Returns ``(wh, cost)``; both values are
|
||||
``None`` when progress is too low or there is no energy yet. Never raises.
|
||||
|
||||
``cost_so_far`` is the dynamic-tariff cost already incurred (#426): the energy
|
||||
consumed so far, charged at the price in force when it was consumed. When it
|
||||
is given, only the *remaining* energy is charged at the current price, so a
|
||||
cycle that ran through a cheap window is not retroactively repriced at the
|
||||
expensive one it happens to be in now. The future half is still the current
|
||||
price - forecasting the tariff is deliberately out of scope.
|
||||
|
||||
``cost_so_far_wh`` is the energy ``cost_so_far`` was charged for, which is NOT
|
||||
``energy_so_far``: the cost integrates the power trace while ``energy_so_far``
|
||||
is the detector's per-reading accumulator, and the two count outages and
|
||||
sub-threshold intervals differently. Subtracting the wrong one leaves the
|
||||
overlap double-charged or uncharged. Defaults to ``energy_so_far`` so a caller
|
||||
that has only the cost keeps the previous behaviour.
|
||||
"""
|
||||
logger = logger or _LOGGER
|
||||
try:
|
||||
@@ -820,7 +836,19 @@ def projected_energy(
|
||||
price_val = float(price)
|
||||
except (TypeError, ValueError):
|
||||
price_val = None
|
||||
cost = (projected_wh / 1000.0) * price_val if price_val is not None else None
|
||||
if price_val is None:
|
||||
cost = None
|
||||
elif cost_so_far is None:
|
||||
cost = (projected_wh / 1000.0) * price_val
|
||||
else:
|
||||
charged_wh = energy_so_far
|
||||
if cost_so_far_wh is not None:
|
||||
try:
|
||||
charged_wh = float(cost_so_far_wh)
|
||||
except (TypeError, ValueError):
|
||||
charged_wh = energy_so_far
|
||||
remaining_wh = max(0.0, projected_wh - charged_wh)
|
||||
cost = float(cost_so_far) + (remaining_wh / 1000.0) * price_val
|
||||
return projected_wh, cost
|
||||
except Exception: # noqa: BLE001 - projection must never break estimates
|
||||
return None, None
|
||||
|
||||
Reference in New Issue