112 files
This commit is contained in:
@@ -31,6 +31,7 @@
|
||||
"auto_start_stop": "Auto start and stop",
|
||||
"valve_regulation": "Valve regulation configuration",
|
||||
"sync_device_internal_temp": "Synchronize device temperature",
|
||||
"humidity": "Humidity",
|
||||
"lock": "Lock",
|
||||
"heating_failure_detection": "Heating failure detection",
|
||||
"auto_tpi_configuration": "Auto TPI - Configuration",
|
||||
@@ -110,6 +111,10 @@
|
||||
"auto_regulation_mode": "Self-regulation",
|
||||
"auto_regulation_dtemp": "Regulation threshold",
|
||||
"auto_regulation_periode_min": "Regulation minimum period",
|
||||
"opening_threshold_degree": "Opening threshold degree",
|
||||
"min_opening_degrees": "Min opening degrees",
|
||||
"max_opening_degrees": "Max opening degrees",
|
||||
"max_closing_degree": "Max closing degree",
|
||||
"auto_regulation_use_device_temp": "Use internal temperature of the underlying",
|
||||
"inverse_switch_command": "Inverse switch command",
|
||||
"auto_fan_mode": "Auto fan mode",
|
||||
@@ -127,6 +132,10 @@
|
||||
"auto_regulation_mode": "Auto adjustment of the target temperature",
|
||||
"auto_regulation_dtemp": "The threshold in ° (or % for valve) under which the temperature change will not be sent",
|
||||
"auto_regulation_periode_min": "Duration in minutes between two regulation update",
|
||||
"opening_threshold_degree": "Valve opening value under which the valve should be considered as closed (and then 'max_closing_degree' will apply)",
|
||||
"min_opening_degrees": "Opening degree minimum value for each underlying device when previous threshold is exceeded, comma separated. Default to 0. Example: 20, 25, 30",
|
||||
"max_opening_degrees": "Opening degree maximum value. The valve will never open more than this value",
|
||||
"max_closing_degree": "Closing degree maximum value. The valve will never be closed above this value. Set it to 100 to fully close the valve",
|
||||
"auto_regulation_use_device_temp": "Use the eventual internal temperature sensor of the underlying to speedup the self-regulation (not needed in most cases)",
|
||||
"inverse_switch_command": "For switch with pilot wire and diode you may need to inverse the command",
|
||||
"auto_fan_mode": "Automatically activate fan when huge heating/cooling is necessary",
|
||||
@@ -353,6 +362,18 @@
|
||||
"sync_entity_ids": "The list of the entities used to synchronize the internal temperature of the underlying devices. There should be one per underlying device. Should be a calibration entity if checkbox is selected or a temperature entity otherwise. Both are `number` entities."
|
||||
}
|
||||
},
|
||||
"humidity": {
|
||||
"title": "Humidity",
|
||||
"description": "Use an external humidity sensor. Detected sensor: {humidity_detected}",
|
||||
"data": {
|
||||
"use_humidity_feature": "Use humidity sensor",
|
||||
"humidity_sensor_entity_id": "Humidity sensor"
|
||||
},
|
||||
"data_description": {
|
||||
"use_humidity_feature": "Disable this option to use the underlying climate humidity only.",
|
||||
"humidity_sensor_entity_id": "Leave empty to automatically use the detected sensor."
|
||||
}
|
||||
},
|
||||
"heating_failure_detection": {
|
||||
"title": "Heating failure detection",
|
||||
"description": "Configure the heating failure detection feature. This detects anomalies when heating is expected but temperature doesn't increase, or when heating is off but temperature keeps rising.",
|
||||
@@ -386,6 +407,7 @@
|
||||
"sync_device_internal_temp_nb_entities_incorrect": "The number of entities for synchronize device internal temperature should be equal to the number of underlyings",
|
||||
"min_opening_degrees_format": "A comma separated list of positive integer is expected. Example: 20, 25, 30",
|
||||
"max_opening_degrees_format": "A comma separated list of positive integer between 0 and the max valve opening is expected. Example: 80, 85, 90",
|
||||
"valve_control_parameters_cardinality_incorrect": "The minimum and maximum opening degree lists cannot contain more values than the configured valves",
|
||||
"min_max_opening_degrees_inconsistent": "For each underlying device, max_opening_degrees must be strictly greater than min_opening_degrees. Please check your configuration.",
|
||||
"vswitch_configuration_incorrect": "The command customization configuration is incorrect. It is required for underlying entities that are not switches, and the format must be service_name[/attribute:value]. More information is available in the README"
|
||||
},
|
||||
@@ -424,6 +446,7 @@
|
||||
"auto_start_stop": "Auto start and stop",
|
||||
"valve_regulation": "Valve regulation configuration",
|
||||
"sync_device_internal_temp": "Synchronize device temperature",
|
||||
"humidity": "Humidity",
|
||||
"lock": "Lock",
|
||||
"heating_failure_detection": "Heating failure detection",
|
||||
"finalize": "All done",
|
||||
@@ -498,6 +521,10 @@
|
||||
"auto_regulation_mode": "Self-regulation",
|
||||
"auto_regulation_dtemp": "Regulation threshold",
|
||||
"auto_regulation_periode_min": "Regulation minimum period",
|
||||
"opening_threshold_degree": "Opening threshold degree",
|
||||
"min_opening_degrees": "Min opening degrees",
|
||||
"max_opening_degrees": "Max opening degrees",
|
||||
"max_closing_degree": "Max closing degree",
|
||||
"auto_regulation_use_device_temp": "Use internal temperature of the underlying",
|
||||
"inverse_switch_command": "Inverse switch command",
|
||||
"auto_fan_mode": "Auto fan mode",
|
||||
@@ -515,6 +542,10 @@
|
||||
"auto_regulation_mode": "Auto adjustment of the target temperature",
|
||||
"auto_regulation_dtemp": "The threshold in ° (or % for valve) under which the temperature change will not be sent",
|
||||
"auto_regulation_periode_min": "Duration in minutes between two regulation update",
|
||||
"opening_threshold_degree": "Valve opening value under which the valve should be considered as closed (and then 'max_closing_degree' will apply)",
|
||||
"min_opening_degrees": "Opening degree minimum value for each underlying device when previous threshold is exceeded, comma separated. Default to 0. Example: 20, 25, 30",
|
||||
"max_opening_degrees": "Opening degree maximum value. The valve will never open more than this value",
|
||||
"max_closing_degree": "Closing degree maximum value. The valve will never be closed above this value. Set it to 100 to fully close the valve",
|
||||
"auto_regulation_use_device_temp": "Use the eventual internal temperature sensor of the underlying to speedup the self-regulation (not needed in most cases)",
|
||||
"inverse_switch_command": "For switch with pilot wire and diode you may need to inverse the command",
|
||||
"auto_fan_mode": "Automatically activate fan when huge heating/cooling is necessary",
|
||||
@@ -697,6 +728,18 @@
|
||||
"sync_entity_ids": "The list of the entities used to synchronize the internal temperature of the underlying devices. There should be one per underlying device. Should be a calibration entity if checkbox is selected or a temperature entity otherwise. Both are `number` entities."
|
||||
}
|
||||
},
|
||||
"humidity": {
|
||||
"title": "Humidity - {name}",
|
||||
"description": "Use an external humidity sensor. Detected sensor: {humidity_detected}",
|
||||
"data": {
|
||||
"use_humidity_feature": "Use humidity sensor",
|
||||
"humidity_sensor_entity_id": "Humidity sensor"
|
||||
},
|
||||
"data_description": {
|
||||
"use_humidity_feature": "Disable this option to use the underlying climate humidity only.",
|
||||
"humidity_sensor_entity_id": "Leave empty to automatically use the detected sensor."
|
||||
}
|
||||
},
|
||||
"auto_tpi_configuration": {
|
||||
"title": "Auto TPI - Configuration - {name}",
|
||||
"description": "General settings for Auto TPI learning.",
|
||||
@@ -776,6 +819,7 @@
|
||||
"sync_device_internal_temp_nb_entities_incorrect": "The number of entities for synchronize device internal temperature should be equal to the number of underlyings",
|
||||
"min_opening_degrees_format": "A comma separated list of positive integer is expected. Example: 20, 25, 30",
|
||||
"max_opening_degrees_format": "A comma separated list of positive integer between 0 and the max value of the valve is expected. Example: 80, 85, 90",
|
||||
"valve_control_parameters_cardinality_incorrect": "The minimum and maximum opening degree lists cannot contain more values than the configured valves",
|
||||
"min_max_opening_degrees_inconsistent": "For each underlying device, max_opening_degrees must be strictly greater than min_opening_degrees. Please check your configuration.",
|
||||
"vswitch_configuration_incorrect": "The command customization configuration is incorrect. It is required for underlying entities that are not switches, and the format must be service_name[/attribute:value]. More information is available in the README"
|
||||
},
|
||||
@@ -963,6 +1007,10 @@
|
||||
}
|
||||
},
|
||||
"services": {
|
||||
"set_hvac_mode_sleep": {
|
||||
"name": "Set HVAC Mode to Sleep",
|
||||
"description": "Sets a VTherm to seasonal sleep. It is shown as off and, for over_climate with direct valve regulation and over_valve, sends a raw 100% valve-opening request. The physical opening remains subject to configured valve control and number entity limits."
|
||||
},
|
||||
"set_auto_tpi_mode": {
|
||||
"name": "Set Auto TPI mode",
|
||||
"description": "Enable or disable the Auto TPI learning mode",
|
||||
|
||||
Reference in New Issue
Block a user