186 files
This commit is contained in:
@@ -9,6 +9,7 @@ from homeassistant.const import (
|
||||
STATE_OFF,
|
||||
STATE_UNAVAILABLE,
|
||||
STATE_UNKNOWN,
|
||||
UnitOfEnergy,
|
||||
)
|
||||
|
||||
from homeassistant.core import (
|
||||
@@ -43,6 +44,7 @@ class FeaturePowerManager(BaseFeatureManager):
|
||||
self._overpowering_state: str | None = None
|
||||
self._is_configured: bool = False
|
||||
self._device_power: float = 0
|
||||
self._power_unit: str = POWER_UNIT_WATT
|
||||
self._use_power_feature: bool = False
|
||||
|
||||
@overrides
|
||||
@@ -52,7 +54,19 @@ class FeaturePowerManager(BaseFeatureManager):
|
||||
# Power management
|
||||
self._power_temp = entry_infos.get(CONF_PRESET_POWER)
|
||||
|
||||
self._device_power = entry_infos.get(CONF_DEVICE_POWER) or 0
|
||||
configured_power_unit = to_internal_power_unit(entry_infos.get(CONF_POWER_UNIT))
|
||||
if configured_power_unit not in (POWER_UNIT_WATT, POWER_UNIT_KILO_WATT):
|
||||
_LOGGER.warning(
|
||||
"%s - Unsupported power unit %s. Falling back to W",
|
||||
self,
|
||||
entry_infos.get(CONF_POWER_UNIT),
|
||||
)
|
||||
self._power_unit = POWER_UNIT_WATT
|
||||
else:
|
||||
self._power_unit = configured_power_unit
|
||||
# Normalize device_power to internal Watts based on configured unit
|
||||
raw_device_power = entry_infos.get(CONF_DEVICE_POWER)
|
||||
self._device_power = (power_to_watts(raw_device_power, self._power_unit) or 0.0) if raw_device_power else 0.0
|
||||
self._use_power_feature = entry_infos.get(CONF_USE_POWER_FEATURE, False)
|
||||
self._is_configured = False
|
||||
|
||||
@@ -92,26 +106,35 @@ class FeaturePowerManager(BaseFeatureManager):
|
||||
}
|
||||
)
|
||||
if self._is_configured:
|
||||
central = vtherm_api.central_power_manager
|
||||
power_unit = self.power_unit
|
||||
central_power_unit = central.power_unit
|
||||
extra_state_attributes.update(
|
||||
{
|
||||
"power_manager": {
|
||||
"power_sensor_entity_id": vtherm_api.central_power_manager.power_sensor_entity_id,
|
||||
"max_power_sensor_entity_id": vtherm_api.central_power_manager.max_power_sensor_entity_id,
|
||||
"power_sensor_entity_id": central.power_sensor_entity_id,
|
||||
"max_power_sensor_entity_id": central.max_power_sensor_entity_id,
|
||||
"overpowering_state": self.overpowering_state,
|
||||
"device_power": self._device_power,
|
||||
"device_power": self.from_watts(self._device_power, power_unit),
|
||||
"power_temp": self._power_temp,
|
||||
"current_power": vtherm_api.central_power_manager.current_power,
|
||||
"current_max_power": vtherm_api.central_power_manager.current_max_power,
|
||||
"mean_cycle_power": self.mean_cycle_power,
|
||||
"current_power": central.from_watts(central.current_power, central_power_unit),
|
||||
"current_max_power": central.from_watts(central.current_max_power, central_power_unit),
|
||||
"mean_cycle_power": self.from_watts(self.mean_cycle_power, power_unit),
|
||||
"power_unit": power_unit,
|
||||
"energy_unit": self.energy_unit,
|
||||
"central_power_unit": central_power_unit,
|
||||
}
|
||||
}
|
||||
)
|
||||
else:
|
||||
power_unit = self.power_unit
|
||||
extra_state_attributes.update(
|
||||
{
|
||||
"power_manager": {
|
||||
"device_power": self._device_power,
|
||||
"mean_cycle_power": self.mean_cycle_power,
|
||||
"device_power": self.from_watts(self._device_power, power_unit),
|
||||
"mean_cycle_power": self.from_watts(self.mean_cycle_power, power_unit),
|
||||
"power_unit": power_unit,
|
||||
"energy_unit": self.energy_unit,
|
||||
}
|
||||
}
|
||||
)
|
||||
@@ -135,9 +158,7 @@ class FeaturePowerManager(BaseFeatureManager):
|
||||
current_power = vtherm_api.central_power_manager.current_power
|
||||
current_max_power = vtherm_api.central_power_manager.current_max_power
|
||||
started_vtherm_total_power = vtherm_api.central_power_manager.started_vtherm_total_power
|
||||
current_started_power = vtherm_api.central_power_manager.get_started_vtherm_power(
|
||||
effective_reservation_key
|
||||
)
|
||||
current_started_power = vtherm_api.central_power_manager.get_started_vtherm_power(effective_reservation_key)
|
||||
if (
|
||||
current_power is None
|
||||
or current_max_power is None
|
||||
@@ -334,9 +355,20 @@ class FeaturePowerManager(BaseFeatureManager):
|
||||
|
||||
@property
|
||||
def device_power(self) -> float:
|
||||
"""Return the device power"""
|
||||
"""Return the device power (normalized in Watts)"""
|
||||
|
||||
return self._device_power
|
||||
|
||||
@property
|
||||
def power_unit(self) -> str:
|
||||
"""Return the configured power unit of the VTherm ("W" or "kW")"""
|
||||
return to_legal_power_unit(self._power_unit)
|
||||
|
||||
@property
|
||||
def energy_unit(self) -> str:
|
||||
"""Return the energy unit matching the configured power unit"""
|
||||
return UnitOfEnergy.WATT_HOUR if self._power_unit == POWER_UNIT_WATT else UnitOfEnergy.KILO_WATT_HOUR
|
||||
|
||||
@property
|
||||
def mean_cycle_power(self) -> float | None:
|
||||
"""Returns the mean power consumption during the cycle"""
|
||||
@@ -359,5 +391,13 @@ class FeaturePowerManager(BaseFeatureManager):
|
||||
"""Return a stable fallback key for temporary power reservations."""
|
||||
return getattr(self._vtherm, "entity_id", None) or self._vtherm.name
|
||||
|
||||
def to_watts(self, power: float | None, unit: str | None) -> float | None:
|
||||
"""Convert a power value to Watts"""
|
||||
return power_to_watts(power, unit)
|
||||
|
||||
def from_watts(self, power_w: float | None, target_unit: str | None) -> float | None:
|
||||
"""Convert a Watts value to the target power unit"""
|
||||
return power_from_watts(power_w, target_unit)
|
||||
|
||||
def __str__(self):
|
||||
return f"PowerManager-{self.name}"
|
||||
|
||||
Reference in New Issue