186 files
This commit is contained in:
1 parent
6be1e92941
commit
bd8280defe
186 files changed
+14904
-1087
No files matched your search
@@ -212,8 +212,29 @@ class ThermostatOverValve(ThermostatProp[UnderlyingValve]): # pylint: disable=a
|
||||
# Temperature not yet available; preserve the current valve position.
|
||||
return
|
||||
|
||||
self.apply_valve_command_percent(current_on_percent, force=True)
|
||||
|
||||
def apply_valve_command_percent(
|
||||
self,
|
||||
on_percent: float,
|
||||
force: bool = False,
|
||||
) -> float:
|
||||
"""Accept a requested valve command and return the retained ratio.
|
||||
|
||||
This is the single conversion point between a proportional algorithm's
|
||||
continuous output and the integer command exposed by the thermostat.
|
||||
"""
|
||||
self.stop_recalculate_later()
|
||||
|
||||
if self._auto_regulation_period_min is None or self._auto_regulation_dpercent is None:
|
||||
_LOGGER.warning(
|
||||
"%s - auto_regulation_period_min or auto_regulation_dpercent is not set. Keeping current valve command.",
|
||||
self,
|
||||
)
|
||||
return self.valve_open_percent / 100.0
|
||||
|
||||
new_valve_percent = round(
|
||||
max(0, min(current_on_percent, 1)) * 100
|
||||
max(0, min(on_percent, 1)) * 100
|
||||
)
|
||||
|
||||
# Issue 533 - don't filter with dtemp if valve should be close. Else it will never close
|
||||
@@ -233,11 +254,23 @@ class ThermostatOverValve(ThermostatProp[UnderlyingValve]): # pylint: disable=a
|
||||
dpercent,
|
||||
)
|
||||
|
||||
return
|
||||
return self.valve_open_percent / 100.0
|
||||
|
||||
if self._valve_open_percent == new_valve_percent:
|
||||
_LOGGER.debug("%s - no change in valve_open_percent.", self)
|
||||
return
|
||||
return self.valve_open_percent / 100.0
|
||||
|
||||
now = self.now
|
||||
if self._last_calculation_timestamp is not None:
|
||||
period = (now - self._last_calculation_timestamp).total_seconds() / 60
|
||||
if not force and period < self._auto_regulation_period_min:
|
||||
_LOGGER.info(
|
||||
"%s - do not apply valve command because regulation_period (%d) is not exceeded",
|
||||
self,
|
||||
period,
|
||||
)
|
||||
self.do_recalculate_later()
|
||||
return self.valve_open_percent / 100.0
|
||||
|
||||
self._valve_open_percent = new_valve_percent
|
||||
|
||||
@@ -249,6 +282,7 @@ class ThermostatOverValve(ThermostatProp[UnderlyingValve]): # pylint: disable=a
|
||||
# self.calculate_hvac_action()
|
||||
self.update_custom_attributes()
|
||||
self.async_write_ha_state()
|
||||
return self.valve_open_percent / 100.0
|
||||
|
||||
def do_recalculate_later(self):
|
||||
"""A utility function to set the valve open percent later on all underlyings"""
|
||||
|
||||
Reference in new issue