@@ -54,6 +54,7 @@ from homeassistant.helpers import translation
from .const import (
DOMAIN,
CONF_POWER_SENSOR,
CONF_PROFILE_EVIDENCE_SOURCES,
CONF_MIN_POWER,
CONF_OFF_DELAY,
CONF_NOTIFY_SERVICE,
@@ -113,6 +114,9 @@ from .const import (
CONF_ANTI_WRINKLE_IDLE_TIMEOUT,
CONF_DISHWASHER_END_SPIKE_QUIET_RELEASE,
DISHWASHER_END_SPIKE_QUIET_RELEASE_SECONDS,
CONF_SMART_TERMINATION_DURATION_RATIO,
DEFAULT_SMART_TERMINATION_DURATION_RATIO,
DEFAULT_SMART_TERMINATION_DURATION_RATIO_BY_DEVICE,
CONF_DELAY_START_DETECT_ENABLED,
CONF_DELAY_CONFIRM_SECONDS,
CONF_DELAY_TIMEOUT_HOURS,
@@ -142,6 +146,7 @@ from .const import (
DEFAULT_SAMPLING_INTERVAL,
DEFAULT_PROGRESS_RESET_DELAY,
DEFAULT_POWER_OFF_THRESHOLD_W,
DEFAULT_PROFILE_EVIDENCE_SOURCES,
DEFAULT_POWER_OFF_DELAY,
DEFAULT_LEARNING_CONFIDENCE,
DEFAULT_DURATION_TOLERANCE,
@@ -223,6 +228,10 @@ from .const import (
DEFAULT_MAX_FULL_TRACES_UNLABELED,
DEFAULT_DTW_BANDWIDTH,
DEFAULT_WATCHDOG_INTERVAL,
resolve_sampling_interval_default,
resolve_watchdog_interval_default,
resolve_start_duration_default,
resolve_smart_termination_duration_ratio_default,
CONF_MATCH_PERSISTENCE,
DEFAULT_MATCH_PERSISTENCE,
DEFAULT_MATCH_REVERT_RATIO,
@@ -593,6 +602,11 @@ class WashDataManager:
# Stage-4 energy discriminator: integrated energy for WM/washer-dryer,
# mean power elsewhere (see analysis.stage4_energy_mode).
self.profile_store.energy_mode = analysis.stage4_energy_mode(self.device_type)
# Which cycle categories may shape a profile. The store cannot read entry
# options, so the manager pushes this in (same as energy_mode above).
self.profile_store.evidence_sources = config_entry.options.get(
CONF_PROFILE_EVIDENCE_SOURCES, DEFAULT_PROFILE_EVIDENCE_SOURCES
)
self.learning_manager = LearningManager(
hass, self.entry_id, self.profile_store, self.device_type,
device_name=config_entry.title,
@@ -707,7 +721,8 @@ class WashDataManager:
start_duration_threshold = float(
config_entry.options.get(
CONF_START_DURATION_THRESHOLD, DEFAULT_START_DURATION_THRESHOLD
CONF_START_DURATION_THRESHOLD,
resolve_start_duration_default(self.device_type),
)
)
end_repeat_count = int(
@@ -779,6 +794,16 @@ class WashDataManager:
CONF_PROFILE_MATCH_INTERVAL, DEFAULT_PROFILE_MATCH_INTERVAL
)
),
# `profile_match_threshold` was stored on the ProfileStore and never read
# anywhere, so the #288 workaround (raise it so near-duplicate profiles
# stop being trusted mid-cycle) silently did nothing. Wire it to the gate
# it was always documented to control; the default is the value that used
# to be hard-coded there, so nothing changes unless it was tuned.
match_confidence_threshold=float(
config_entry.options.get(
CONF_PROFILE_MATCH_THRESHOLD, DEFAULT_PROFILE_MATCH_THRESHOLD
)
),
anti_wrinkle_enabled=bool(
config_entry.options.get(
CONF_ANTI_WRINKLE_ENABLED, DEFAULT_ANTI_WRINKLE_ENABLED
@@ -810,6 +835,15 @@ class WashDataManager:
DISHWASHER_END_SPIKE_QUIET_RELEASE_SECONDS,
)
),
# #393: resolve the device-type default HERE (not in the gate) so the
# field always carries a real float - playground.effective_settings()
# skips a None-valued field, which would desync the sim from the detector.
smart_termination_duration_ratio=float(
config_entry.options.get(
CONF_SMART_TERMINATION_DURATION_RATIO,
resolve_smart_termination_duration_ratio_default(self.device_type),
)
),
delay_detect_enabled=bool(
config_entry.options.get(
CONF_DELAY_START_DETECT_ENABLED, DEFAULT_DELAY_START_DETECT_ENABLED
@@ -903,13 +937,19 @@ class WashDataManager:
self._remove_external_trigger_listener = None # External cycle end trigger
self._remove_watchdog = None
self._watchdog_interval = int(
config_entry.options.get(CONF_WATCHDOG_INTERVAL, DEFAULT_WATCHDOG_INTERVAL)
config_entry.options.get(
CONF_WATCHDOG_INTERVAL,
resolve_watchdog_interval_default(self.device_type),
)
)
self._match_persistence = int(
config_entry.options.get(CONF_MATCH_PERSISTENCE, DEFAULT_MATCH_PERSISTENCE)
)
self._sampling_interval = float(
config_entry.options.get(CONF_SAMPLING_INTERVAL, DEFAULT_SAMPLING_INTERVAL)
config_entry.options.get(
CONF_SAMPLING_INTERVAL,
resolve_sampling_interval_default(self.device_type),
)
)
self._noise_events_threshold = int(
config_entry.options.get(
@@ -1427,10 +1467,15 @@ class WashDataManager:
# Push updates to detector
self.detector.set_verified_pause(verified_pause)
# Element 8 is the narrow #288-only prefix verdict and element 9 the
# matched profile's own tail power level, both for the #364 guards. The
# detector tolerates shorter tuples, so other callers stay valid.
self.detector.update_match(
(profile_name, confidence, matched_duration, phase_name,
result.is_confident_mismatch, result.is_ambiguous,
result.is_prefix_ambiguous)
result.is_prefix_ambiguous,
result.is_prefix_ambiguous_full_shape,
self.profile_store.profile_tail_power(profile_name) if profile_name else None)
)
# --- LOGGING (Unified) ---
@@ -2093,12 +2138,36 @@ class WashDataManager:
CONF_PROFILE_MATCH_INTERVAL, DEFAULT_PROFILE_MATCH_INTERVAL
)
)
# Keep the detector's copy in sync so a panel edit takes effect without a
# restart, exactly like min_duration_ratio below.
self.detector.config.match_confidence_threshold = float(
config_entry.options.get(
CONF_PROFILE_MATCH_THRESHOLD, DEFAULT_PROFILE_MATCH_THRESHOLD
)
)
self.profile_store.dtw_bandwidth = float(
config_entry.options.get(CONF_DTW_BANDWIDTH, DEFAULT_DTW_BANDWIDTH)
)
# Stage-4 energy discriminator: integrated energy for WM/washer-dryer,
# mean power elsewhere (see analysis.stage4_energy_mode).
self.profile_store.energy_mode = analysis.stage4_energy_mode(self.device_type)
# Which cycle categories may shape a profile. Changing it changes every
# profile's curve, so rebuild them all now: envelopes are otherwise only rebuilt
# on a cycle end or a label change, so the user would tick the box and see
# nothing happen for days.
_prev_evidence = self.profile_store.evidence_sources
self.profile_store.evidence_sources = config_entry.options.get(
CONF_PROFILE_EVIDENCE_SOURCES, DEFAULT_PROFILE_EVIDENCE_SOURCES
)
if self.profile_store.evidence_sources != _prev_evidence:
self._logger.info(
"Profile evidence sources changed %s -> %s; rebuilding all envelopes",
list(_prev_evidence), list(self.profile_store.evidence_sources),
)
# Tracked, not fire-and-forget: this writes to the ProfileStore, so a
# reload/unload mid-rebuild must be able to cancel it before the store is
# swapped out (see _spawn_tracked).
self._spawn_tracked(self.profile_store.async_rebuild_all_envelopes())
# Device default
dev_def = DEVICE_COMPLETION_THRESHOLDS.get(
@@ -2110,7 +2179,8 @@ class WashDataManager:
new_start_threshold = float(
config_entry.options.get(
CONF_START_DURATION_THRESHOLD, DEFAULT_START_DURATION_THRESHOLD
CONF_START_DURATION_THRESHOLD,
resolve_start_duration_default(self.device_type),
)
)
new_end_repeat_count = int(
@@ -2180,6 +2250,12 @@ class WashDataManager:
DISHWASHER_END_SPIKE_QUIET_RELEASE_SECONDS,
)
)
new_smart_termination_duration_ratio = float(
config_entry.options.get(
CONF_SMART_TERMINATION_DURATION_RATIO,
resolve_smart_termination_duration_ratio_default(self.device_type),
)
)
new_delay_detect_enabled = bool(
config_entry.options.get(
CONF_DELAY_START_DETECT_ENABLED, DEFAULT_DELAY_START_DETECT_ENABLED
@@ -2219,6 +2295,7 @@ class WashDataManager:
self.detector.config.anti_wrinkle_exit_power = new_anti_wrinkle_exit_power
self.detector.config.anti_wrinkle_idle_timeout = new_anti_wrinkle_idle_timeout
self.detector.config.dishwasher_end_spike_quiet_release = new_dishwasher_end_spike_quiet_release
self.detector.config.smart_termination_duration_ratio = new_smart_termination_duration_ratio
self.detector.config.delay_detect_enabled = new_delay_detect_enabled
self.detector.config.delay_confirm_seconds = new_delay_confirm_seconds
self.detector.config.delay_timeout_seconds = new_delay_timeout_seconds
@@ -2414,7 +2491,10 @@ class WashDataManager:
# Update sampling interval
old_sampling = self._sampling_interval
new_sampling = float(
config_entry.options.get(CONF_SAMPLING_INTERVAL, DEFAULT_SAMPLING_INTERVAL)
config_entry.options.get(
CONF_SAMPLING_INTERVAL,
resolve_sampling_interval_default(self.device_type),
)
)
if old_sampling != new_sampling:
self._sampling_interval = new_sampling
@@ -2422,6 +2502,26 @@ class WashDataManager:
"Updated sampling interval: %.1fs -> %.1fs", old_sampling, new_sampling
)
# Watchdog cadence: like sampling above, this was only read at construction, so a
# changed CONF_WATCHDOG_INTERVAL (or a device-type change selecting a new default)
# otherwise kept the old cadence until the manager was recreated. Re-arm an active
# watchdog so the new interval takes effect mid-cycle.
old_watchdog = self._watchdog_interval
new_watchdog = int(
config_entry.options.get(
CONF_WATCHDOG_INTERVAL,
resolve_watchdog_interval_default(self.device_type),
)
)
if old_watchdog != new_watchdog:
self._watchdog_interval = new_watchdog
self._logger.info(
"Updated watchdog interval: %ds -> %ds", old_watchdog, new_watchdog
)
if self._remove_watchdog: # active cycle: cancel and re-register at the new cadence
self._stop_watchdog()
self._start_watchdog()
# RESTORE STATE (only if recent enough, otherwise treat as stale)
await self._attempt_state_restoration()
@@ -3218,8 +3318,24 @@ class WashDataManager:
):
return
# Track observed power readings for learning
self.learning_manager.process_power_reading(power, now, self._last_reading_time)
# Track observed power readings for learning - only while a cycle is
# active (#394). An appliance is idle ~98% of the time; running the 5-min
# auto-tune pass and training the sample-interval cadence model on the
# standby heartbeat is constant background work (a store rewrite every few
# minutes) that buys nothing AND skews every operational suggestion, since
# the idle publish-on-change heartbeat is not the in-cycle sampling
# cadence those suggestions are sized from. The detector below still
# receives EVERY reading, so the next cycle's start is never missed - only
# the learning call is gated.
if self.detector.state in (
STATE_STARTING,
STATE_RUNNING,
STATE_PAUSED,
STATE_ENDING,
):
self.learning_manager.process_power_reading(
power, now, self._last_reading_time
)
self._last_reading_time = now
self._last_real_reading_time = now # Track real update
self._current_power = power
@@ -3635,6 +3751,20 @@ class WashDataManager:
if not self._last_reading_time:
return
# Refresh the remaining-time / progress estimate on the watchdog cadence
# (sampling-derived: max(30, 2*sampling+1)s), independently of incoming power
# events. A publish-on-change plug emits nothing during a flat low-power tail
# (e.g. a dishwasher's ~30 min drying phase at 0 W), so the event-driven
# _update_remaining_only never runs and the displayed countdown freezes at
# whatever value it last showed. The estimate is wall-clock based
# (net_elapsed_seconds), so this tick advances it correctly with zero new
# readings; it no-ops until a profile is matched. Kept ahead of the
# keepalive/force-end branches below so even a verified-pause drying tail
# (which skips those branches) still ticks down.
if self.detector.state in (STATE_RUNNING, STATE_PAUSED, STATE_ENDING):
self._update_remaining_only()
self._notify_update()
time_since_any_update = (now - self._last_reading_time).total_seconds()
# Calculate time since REAL update (if available, else fallback to any update)
@@ -6742,6 +6872,9 @@ class WashDataManager:
current_duration,
profile_name,
self._logger,
quiet_threshold_w=float(
getattr(self.detector.config, "stop_threshold_w", 0.0) or 0.0
),
)
def _notify_update(self) -> None: