# Downstairs Bathroom Light - Debug Session (2026-07-24) ## Issue Motion sensor triggers but bathroom light has a 20-30 second delay turning on. ## Key Entities - `automation.downstairs_bathroom_light_contro` — automation (mode: restart, working correctly) - `binary_sensor.downstairs_bathroom_occupancy` — Third Reality Zigbee motion sensor (Z2M) - `switch.downstairs_bathroom_switch` — TP-Link HS200 (exposed via Homebridge) - `light.bathroom_light` — TP-Link HS220 dimmer (separate device, NOT controlled by automation) ## Findings 1. Automation logic is correct — triggers on occupancy on/off, 30-min timeout, mode restart 2. Automation IS firing and switch IS turning on (confirmed via history) 3. The delay is between automation trigger and switch responding — suggests Homebridge communication delay 4. No other HA automations reference this switch 5. User confirmed no HomeKit/TP-Link app automations interfering 6. User tried restarting Homebridge — delay persisted 7. User was about to restart entire HA server to test ## Resolution (2026-07-23) Full HA server restart resolved the issue. Post-reboot trigger-to-action times are all under 0.5s. The delay was caused by a stale Homebridge WebSocket connection to the TP-Link HS200. ## Next Steps If Issue Recurs - Check Homebridge logs for TP-Link communication errors - Consider switching automation to control `light.bathroom_light` (HS220) directly if TP-Link integration is available - Check if Homebridge add-on needs update