{ "config": { "step": { "user": { "title": "Configure Intelligent Heating Pilot", "description": "Set up your Intelligent Heating Pilot (IHP) integration for intelligent preheating calculations based on learned thermal slopes from your VTherm.", "data": { "name": "Integration Name", "vtherm_entity_id": "Versatile Thermostat (VTherm) Entity", "scheduler_entities": "Scheduler Entities (switches)", "humidity_in_entity_id": "Indoor Humidity Sensor (optional)", "humidity_out_entity_id": "Outdoor Humidity Sensor (optional)", "cloud_cover_entity_id": "Cloud Coverage Sensor (optional)", "lhs_retention_days": "Slope Data Retention (days)", "temp_delta_threshold": "Temperature Detection Threshold (°C)", "cycle_split_duration_minutes": "Cycle Split Duration (minutes)", "min_cycle_duration_minutes": "Minimum Cycle Duration (minutes)", "max_cycle_duration_minutes": "Maximum Cycle Duration (minutes)", "task_range_days": "Recorder Extraction Period (days)", "safety_shutoff_grace_minutes": "Safety Shutoff Grace Period (minutes)" }, "data_description": { "vtherm_entity_id": "The Versatile Thermostat to control (source of learned slope)", "scheduler_entities": "The HACS Scheduler Component switches that control this VTherm", "humidity_in_entity_id": "Room humidity sensor to refine calculations", "humidity_out_entity_id": "Outdoor humidity sensor to refine calculations", "cloud_cover_entity_id": "Cloud coverage sensor to account for solar impact", "lhs_retention_days": "Number of days to keep historical slope data", "temp_delta_threshold": "Temperature difference threshold to detect heating cycle start/end (default: 0.2°C). Lower values = more sensitive detection.", "cycle_split_duration_minutes": "Split long heating cycles into sub-cycles of this duration for ML training augmentation (0 = disabled).", "min_cycle_duration_minutes": "Minimum duration to consider a valid heating cycle. Filters out short micro-cycles (noise).", "max_cycle_duration_minutes": "Maximum duration for a single heating cycle. Filters out abnormally long cycles (malfunctions).", "task_range_days": "Number of days per Recorder extraction task. Increase on powerful machines to reduce task count. Decrease on slow machines to reduce query load per task. Default: 7.", "safety_shutoff_grace_minutes": "Grace period in minutes for brief heating interruptions (safety/frost mode). Interruptions shorter than this threshold will not terminate an in-progress cycle. Set to 0 to disable. Default: 10 min." } } }, "error": { "cannot_connect": "Failed to connect", "invalid_auth": "Invalid authentication", "unknown": "Unexpected error", "required": "This field is required" }, "abort": { "already_configured": "This integration is already configured" } }, "options": { "step": { "init": { "title": "Modify Intelligent Heating Pilot Options", "description": "Modify the entities used by Intelligent Heating Pilot", "data": { "vtherm_entity_id": "Versatile Thermostat (VTherm) Entity", "scheduler_entities": "Scheduler Entities (switches)", "humidity_in_entity_id": "Indoor Humidity Sensor (optional)", "humidity_out_entity_id": "Outdoor Humidity Sensor (optional)", "cloud_cover_entity_id": "Cloud Coverage Sensor (optional)", "lhs_retention_days": "Slope Data Retention (days)", "temp_delta_threshold": "Temperature Detection Threshold (°C)", "cycle_split_duration_minutes": "Cycle Split Duration (minutes)", "min_cycle_duration_minutes": "Minimum Cycle Duration (minutes)", "max_cycle_duration_minutes": "Maximum Cycle Duration (minutes)", "task_range_days": "Recorder Extraction Period (days)", "safety_shutoff_grace_minutes": "Safety Shutoff Grace Period (minutes)" }, "data_description": { "temp_delta_threshold": "Temperature difference threshold to detect heating cycle start/end (default: 0.2°C).", "cycle_split_duration_minutes": "Split long cycles into sub-cycles for ML training (leave empty to disable).", "min_cycle_duration_minutes": "Minimum duration to consider a valid heating cycle.", "max_cycle_duration_minutes": "Maximum duration for a single heating cycle.", "task_range_days": "Number of days per Recorder extraction task. Increase on powerful machines to reduce task count. Decrease on slow machines to reduce query load per task. Default: 7.", "safety_shutoff_grace_minutes": "Grace period in minutes for brief heating interruptions (safety/frost mode). Set to 0 to disable. Default: 10 min." } } }, "error": { "required": "This field is required" } } }