# pylint: disable=line-too-long
|
|
""" This file implements the Auto start/stop algorithm as described here: https://github.com/jmcollin78/versatile_thermostat/issues/585
|
|
"""
|
|
|
|
import logging
|
|
from vtherm_api.log_collector import get_vtherm_logger
|
|
from datetime import datetime
|
|
from typing import Literal
|
|
|
|
from .vtherm_hvac_mode import VThermHvacMode, VThermHvacMode_HEAT, VThermHvacMode_COOL
|
|
|
|
from .const import (
|
|
AUTO_START_STOP_LEVEL_NONE,
|
|
AUTO_START_STOP_LEVEL_FAST,
|
|
AUTO_START_STOP_LEVEL_MEDIUM,
|
|
AUTO_START_STOP_LEVEL_SLOW,
|
|
AUTO_START_STOP_LEVEL_VERY_SLOW,
|
|
TYPE_AUTO_START_STOP_LEVELS,
|
|
)
|
|
|
|
|
|
_LOGGER = get_vtherm_logger(__name__)
|
|
|
|
# Some constant to make algorithm depending of level
|
|
DT_MIN = {
|
|
AUTO_START_STOP_LEVEL_NONE: 0, # Not used
|
|
AUTO_START_STOP_LEVEL_VERY_SLOW: 60,
|
|
AUTO_START_STOP_LEVEL_SLOW: 30,
|
|
AUTO_START_STOP_LEVEL_MEDIUM: 15,
|
|
AUTO_START_STOP_LEVEL_FAST: 7,
|
|
}
|
|
|
|
# the measurement cycle (2 min)
|
|
CYCLE_SEC = 120
|
|
|
|
# A temp hysteresis to avoid rapid OFF/ON
|
|
TEMP_HYSTERESIS = 0.5
|
|
|
|
ERROR_THRESHOLD = {
|
|
AUTO_START_STOP_LEVEL_NONE: 0, # Not used
|
|
AUTO_START_STOP_LEVEL_VERY_SLOW: 20, # 20 cycle above 1° or 10 cycle above 2°, ...
|
|
AUTO_START_STOP_LEVEL_SLOW: 10, # 10 cycle above 1° or 5 cycle above 2°, ...
|
|
AUTO_START_STOP_LEVEL_MEDIUM: 5, # 5 cycle above 1° or 3 cycle above 2°, ..., 1 cycle above 5°
|
|
AUTO_START_STOP_LEVEL_FAST: 2, # 2 cycle above 1° or 1 cycle above 2°
|
|
}
|
|
|
|
AUTO_START_STOP_ACTION_OFF = "turnOff"
|
|
AUTO_START_STOP_ACTION_ON = "turnOn"
|
|
AUTO_START_STOP_ACTION_NOTHING = "nothing"
|
|
AUTO_START_STOP_ACTIONS = Literal[ # pylint: disable=invalid-name
|
|
AUTO_START_STOP_ACTION_OFF,
|
|
AUTO_START_STOP_ACTION_ON,
|
|
AUTO_START_STOP_ACTION_NOTHING,
|
|
]
|
|
|
|
class AutoStartStopDetectionAlgorithm:
|
|
"""The class that implements the algorithm listed above"""
|
|
|
|
_dt: float | None = None
|
|
_level: str = AUTO_START_STOP_LEVEL_NONE
|
|
_accumulated_error: float = 0
|
|
_error_threshold: float | None = None
|
|
_last_calculation_date: datetime | None = None
|
|
_last_switch_date: datetime | None = None
|
|
|
|
def __init__(self, level: TYPE_AUTO_START_STOP_LEVELS, vtherm_name: str):
|
|
"""Initalize a new algorithm with the right constants"""
|
|
self._vtherm_name: str = vtherm_name
|
|
self._last_calculation_date: datetime | None = None
|
|
self._last_switch_date: datetime | None = None
|
|
self._init_level(level)
|
|
self._last_should_be_off: bool = False
|
|
|
|
def _init_level(self, level: TYPE_AUTO_START_STOP_LEVELS):
|
|
"""Initialize a new level"""
|
|
if level == self._level:
|
|
return
|
|
|
|
self._level = level
|
|
if self._level != AUTO_START_STOP_LEVEL_NONE:
|
|
self._dt = DT_MIN[level]
|
|
self._error_threshold = ERROR_THRESHOLD[level]
|
|
# reset accumulated error if we change the level
|
|
self._accumulated_error = 0
|
|
|
|
def should_be_turned_off(self, requested_hvac_mode: VThermHvacMode, target_temp: float, current_temp: float, slope_min: float | None, now: datetime) -> bool | None:
|
|
"""Check auto-start/stop state should be triggered
|
|
Return True if the device should be turned off, False if the device should not be turned off
|
|
"""
|
|
|
|
if self._level == AUTO_START_STOP_LEVEL_NONE:
|
|
_LOGGER.debug(
|
|
"%s - auto-start/stop is disabled",
|
|
self,
|
|
)
|
|
self._last_should_be_off = False
|
|
return self._last_should_be_off
|
|
|
|
_LOGGER.debug(
|
|
"%s - calculate_action: requested_hvac_mode=%s, target_temp=%s, current_temp=%s, slope_min=%s at %s",
|
|
self,
|
|
requested_hvac_mode,
|
|
target_temp,
|
|
current_temp,
|
|
slope_min,
|
|
now,
|
|
)
|
|
|
|
if requested_hvac_mode is None or target_temp is None or current_temp is None:
|
|
_LOGGER.debug(
|
|
"%s - No all mandatory parameters are set. Disable auto-start/stop",
|
|
self,
|
|
)
|
|
self._last_should_be_off = False
|
|
return self._last_should_be_off
|
|
|
|
# Calculate the error factor (P)
|
|
error = target_temp - current_temp
|
|
|
|
# reduce the error considering the dt between the last measurement
|
|
if self._last_calculation_date is not None:
|
|
dtmin = (now - self._last_calculation_date).total_seconds() / CYCLE_SEC
|
|
# ignore two calls too near (< 24 sec)
|
|
if dtmin <= 0.2:
|
|
_LOGGER.debug(
|
|
"%s - new calculation of auto_start_stop (%s) is too near of the last one (%s). Forget it",
|
|
self,
|
|
now,
|
|
self._last_calculation_date,
|
|
)
|
|
return self._last_should_be_off
|
|
error = error * dtmin
|
|
|
|
# If the error have change its sign, reset smoothly the accumulated error
|
|
if error * self._accumulated_error < 0:
|
|
self._accumulated_error = self._accumulated_error / 2.0
|
|
|
|
self._accumulated_error += error
|
|
|
|
# Capping of the error
|
|
self._accumulated_error = min(
|
|
self._error_threshold,
|
|
max(-self._error_threshold, self._accumulated_error),
|
|
)
|
|
|
|
self._last_calculation_date = now
|
|
|
|
temp_at_dt = current_temp + slope_min * self._dt
|
|
|
|
# Calculate the number of minute from last_switch
|
|
nb_minutes_since_last_switch = 999
|
|
if self._last_switch_date is not None:
|
|
nb_minutes_since_last_switch = (
|
|
now - self._last_switch_date
|
|
).total_seconds() / 60
|
|
|
|
# Check to turn-off
|
|
# When we hit the threshold, that mean we can turn off
|
|
previous_should_be_off = self._last_should_be_off
|
|
if requested_hvac_mode == VThermHvacMode_HEAT:
|
|
if self._accumulated_error <= -self._error_threshold and temp_at_dt >= target_temp + TEMP_HYSTERESIS and nb_minutes_since_last_switch >= self._dt:
|
|
_LOGGER.info(
|
|
"%s - auto-start/stop: We need to stop, there is no need for heating for a long time.",
|
|
self,
|
|
)
|
|
|
|
self._last_should_be_off = True
|
|
elif temp_at_dt <= target_temp - TEMP_HYSTERESIS and nb_minutes_since_last_switch >= self._dt:
|
|
_LOGGER.info(
|
|
"%s - auto-start/stop: We need to start heating.",
|
|
self,
|
|
)
|
|
self._last_should_be_off = False
|
|
|
|
elif requested_hvac_mode == VThermHvacMode_COOL:
|
|
if self._accumulated_error >= self._error_threshold and temp_at_dt <= target_temp - TEMP_HYSTERESIS and nb_minutes_since_last_switch >= self._dt:
|
|
_LOGGER.info(
|
|
"%s - We need to stop, there is no need for cooling for a long time.",
|
|
self,
|
|
)
|
|
self._last_should_be_off = True
|
|
|
|
elif temp_at_dt >= target_temp + TEMP_HYSTERESIS and nb_minutes_since_last_switch >= self._dt:
|
|
_LOGGER.info(
|
|
"%s - We need to start cooling.",
|
|
self,
|
|
)
|
|
self._last_should_be_off = False
|
|
|
|
_LOGGER.debug("%s - nothing to do, requested hvac_mode is %s", self, requested_hvac_mode)
|
|
if previous_should_be_off != self._last_should_be_off:
|
|
self._last_switch_date = now
|
|
|
|
return self._last_should_be_off
|
|
|
|
# def calculate_action(
|
|
# self,
|
|
# hvac_mode: VThermHvacMode | None,
|
|
# saved_hvac_mode: VThermHvacMode | None,
|
|
# target_temp: float,
|
|
# current_temp: float,
|
|
# slope_min: float | None,
|
|
# now: datetime,
|
|
# ) -> AUTO_START_STOP_ACTIONS:
|
|
# """Calculate an eventual action to do depending of the value in parameter"""
|
|
|
|
# # Check to turn-off
|
|
# # When we hit the threshold, that mean we can turn off
|
|
# if hvac_mode == VThermHvacMode_HEAT:
|
|
# if (
|
|
# self._accumulated_error <= -self._error_threshold
|
|
# and temp_at_dt >= target_temp + TEMP_HYSTERESIS
|
|
# and nb_minutes_since_last_switch >= self._dt
|
|
# ):
|
|
# _LOGGER.info(
|
|
# "%s - We need to stop, there is no need for heating for a long time.",
|
|
# self,
|
|
# )
|
|
# self._last_switch_date = now
|
|
# return AUTO_START_STOP_ACTION_OFF
|
|
# else:
|
|
# _LOGGER.debug("%s - nothing to do, we are heating", self)
|
|
# return AUTO_START_STOP_ACTION_NOTHING
|
|
|
|
# if hvac_mode == VThermHvacMode_COOL:
|
|
# if (
|
|
# self._accumulated_error >= self._error_threshold
|
|
# and temp_at_dt <= target_temp - TEMP_HYSTERESIS
|
|
# and nb_minutes_since_last_switch >= self._dt
|
|
# ):
|
|
# _LOGGER.info(
|
|
# "%s - We need to stop, there is no need for cooling for a long time.",
|
|
# self,
|
|
# )
|
|
# self._last_switch_date = now
|
|
# return AUTO_START_STOP_ACTION_OFF
|
|
# else:
|
|
# _LOGGER.debug(
|
|
# "%s - nothing to do, we are cooling",
|
|
# self,
|
|
# )
|
|
# return AUTO_START_STOP_ACTION_NOTHING
|
|
|
|
# # check to turn on
|
|
# if hvac_mode == VThermHvacMode_OFF and saved_hvac_mode == VThermHvacMode_HEAT:
|
|
# if (
|
|
# temp_at_dt <= target_temp - TEMP_HYSTERESIS
|
|
# and nb_minutes_since_last_switch >= self._dt
|
|
# ):
|
|
# _LOGGER.info(
|
|
# "%s - We need to start, because it will be time to heat",
|
|
# self,
|
|
# )
|
|
# self._last_switch_date = now
|
|
# return AUTO_START_STOP_ACTION_ON
|
|
# else:
|
|
# _LOGGER.debug(
|
|
# "%s - nothing to do, we don't need to heat soon",
|
|
# self,
|
|
# )
|
|
# return AUTO_START_STOP_ACTION_NOTHING
|
|
|
|
# if hvac_mode == VThermHvacMode_OFF and saved_hvac_mode == VThermHvacMode_COOL:
|
|
# if (
|
|
# temp_at_dt >= target_temp + TEMP_HYSTERESIS
|
|
# and nb_minutes_since_last_switch >= self._dt
|
|
# ):
|
|
# _LOGGER.info(
|
|
# "%s - We need to start, because it will be time to cool",
|
|
# self,
|
|
# )
|
|
# self._last_switch_date = now
|
|
# return AUTO_START_STOP_ACTION_ON
|
|
# else:
|
|
# _LOGGER.debug(
|
|
# "%s - nothing to do, we don't need to cool soon",
|
|
# self,
|
|
# )
|
|
# return AUTO_START_STOP_ACTION_NOTHING
|
|
|
|
# _LOGGER.debug(
|
|
# "%s - nothing to do, no conditions applied",
|
|
# self,
|
|
# )
|
|
# return AUTO_START_STOP_ACTION_NOTHING
|
|
|
|
def set_level(self, level: TYPE_AUTO_START_STOP_LEVELS):
|
|
"""Set a new level"""
|
|
self._init_level(level)
|
|
|
|
def reset_switch_delay(self):
|
|
"""Reset the switch delay to allow immediate restart.
|
|
Should be called when target temperature changes significantly (preset change, manual temp change).
|
|
This prevents the VTherm from staying off when the user explicitly requests a higher temperature.
|
|
"""
|
|
_LOGGER.debug("%s - Resetting switch delay to allow immediate start/stop", self)
|
|
self._last_switch_date = None
|
|
# Also reset _last_calculation_date to allow immediate recalculation
|
|
# This is needed because the check for too-rapid calculations would otherwise
|
|
# ignore the next call if it happens within 24 seconds
|
|
self._last_calculation_date = None
|
|
# Reset the last decision so a user-initiated preset/temperature change always exits
|
|
# the auto-stop state. Without this, if neither the "turn on" nor the "turn off"
|
|
# condition is met (e.g. room temp near target with a slightly positive slope),
|
|
# _last_should_be_off would stay True and the VTherm would remain stopped even though
|
|
# the user explicitly asked for a different preset.
|
|
self._last_should_be_off = False
|
|
|
|
@property
|
|
def dt_min(self) -> float:
|
|
"""Get the dt value"""
|
|
return self._dt
|
|
|
|
@property
|
|
def accumulated_error(self) -> float:
|
|
"""Get the accumulated error value"""
|
|
return self._accumulated_error
|
|
|
|
@property
|
|
def accumulated_error_threshold(self) -> float:
|
|
"""Get the accumulated error threshold value"""
|
|
return self._error_threshold
|
|
|
|
@property
|
|
def level(self) -> TYPE_AUTO_START_STOP_LEVELS:
|
|
"""Get the level value"""
|
|
return self._level
|
|
|
|
@property
|
|
def last_switch_date(self) -> datetime | None:
|
|
"""Get the last of the last switch"""
|
|
return self._last_switch_date
|
|
|
|
def __str__(self) -> str:
|
|
return f"AutoStartStopDetectionAlgorithm-{self._vtherm_name}"
|