447 lines
14 KiB
YAML
447 lines
14 KiB
YAML
reload:
|
|
name: Reload
|
|
description: Reload all Versatile Thermostat entities.
|
|
|
|
set_presence:
|
|
name: Set presence
|
|
description: Force the presence mode in thermostat
|
|
target:
|
|
entity:
|
|
integration: versatile_thermostat
|
|
fields:
|
|
presence:
|
|
name: Presence
|
|
description: Presence setting
|
|
required: true
|
|
advanced: false
|
|
example: "on"
|
|
default: "on"
|
|
selector:
|
|
select:
|
|
options:
|
|
- "on"
|
|
- "off"
|
|
- "home"
|
|
- "not_home"
|
|
|
|
set_safety:
|
|
name: Set safety
|
|
description: Change the safety parameters
|
|
target:
|
|
entity:
|
|
integration: versatile_thermostat
|
|
fields:
|
|
delay_min:
|
|
name: Delay in minutes
|
|
description: Maximum allowed delay in minutes between two temperature mesures
|
|
required: false
|
|
advanced: false
|
|
example: "30"
|
|
selector:
|
|
number:
|
|
min: 0
|
|
max: 9999
|
|
unit_of_measurement: "min"
|
|
mode: box
|
|
min_on_percent:
|
|
name: Minimal on_percent
|
|
description: Minimal heating percent value for safety preset activation
|
|
required: false
|
|
advanced: false
|
|
example: "0.5"
|
|
default: "0.5"
|
|
selector:
|
|
number:
|
|
min: 0
|
|
max: 1
|
|
step: 0.05
|
|
unit_of_measurement: "%"
|
|
mode: slider
|
|
default_on_percent:
|
|
name: on_percent used in safety mode
|
|
description: The default heating percent value in safety preset
|
|
required: false
|
|
advanced: false
|
|
example: "0.1"
|
|
default: "0.1"
|
|
selector:
|
|
number:
|
|
min: 0
|
|
max: 1
|
|
step: 0.05
|
|
unit_of_measurement: "%"
|
|
mode: slider
|
|
|
|
set_window_bypass:
|
|
name: Set Window ByPass
|
|
description: Bypass the window state to enable heating with window open.
|
|
target:
|
|
entity:
|
|
integration: versatile_thermostat
|
|
fields:
|
|
window_bypass:
|
|
name: Window ByPass
|
|
description: ByPass value
|
|
required: true
|
|
advanced: false
|
|
default: true
|
|
selector:
|
|
boolean:
|
|
|
|
set_auto_regulation_mode:
|
|
name: Set Auto Regulation mode
|
|
description: Change the mode of self-regulation (only for VTherm over climate)
|
|
target:
|
|
entity:
|
|
integration: versatile_thermostat
|
|
fields:
|
|
auto_regulation_mode:
|
|
name: Auto regulation mode
|
|
description: Possible values
|
|
required: true
|
|
advanced: false
|
|
default: true
|
|
selector:
|
|
select:
|
|
options:
|
|
- "None"
|
|
- "Light"
|
|
- "Medium"
|
|
- "Strong"
|
|
- "Slow"
|
|
- "Expert"
|
|
|
|
set_auto_fan_mode:
|
|
name: Set Auto Fan mode
|
|
description: Change the mode of auto-fan (only for VTherm over climate)
|
|
target:
|
|
entity:
|
|
integration: versatile_thermostat
|
|
fields:
|
|
auto_fan_mode:
|
|
name: Auto fan mode
|
|
description: Possible values
|
|
required: true
|
|
advanced: false
|
|
default: true
|
|
selector:
|
|
select:
|
|
options:
|
|
- "None"
|
|
- "Low"
|
|
- "Medium"
|
|
- "High"
|
|
- "Turbo"
|
|
|
|
set_hvac_mode_sleep:
|
|
name: Set HVAC Mode to Sleep
|
|
description: Turns a VTherm climate into seasonal sleep - OFF with valve 100% open (only for VTherm over climate with valve regulation).
|
|
target:
|
|
entity:
|
|
integration: versatile_thermostat
|
|
|
|
lock:
|
|
name: Lock
|
|
description: "Locks the thermostat, preventing any changes to its configuration from UI or automations."
|
|
target:
|
|
entity:
|
|
integration: versatile_thermostat
|
|
|
|
fields:
|
|
code:
|
|
name: Lock code
|
|
description: The optional lock code
|
|
required: false
|
|
advanced: false
|
|
example: "1234"
|
|
selector:
|
|
text:
|
|
type: password
|
|
|
|
unlock:
|
|
name: Unlock
|
|
description: "Unlocks the thermostat, allowing changes to its configuration."
|
|
target:
|
|
entity:
|
|
integration: versatile_thermostat
|
|
fields:
|
|
code:
|
|
name: Lock code
|
|
description: The optional lock code
|
|
required: false
|
|
advanced: false
|
|
example: "1234"
|
|
selector:
|
|
text:
|
|
type: password
|
|
|
|
set_tpi_parameters:
|
|
name: Set TPI parameters
|
|
description: Change the TPI parameters
|
|
target:
|
|
entity:
|
|
integration: versatile_thermostat
|
|
fields:
|
|
tpi_coef_int:
|
|
name: Coef Int
|
|
description: Coefficient Integral
|
|
required: false
|
|
advanced: false
|
|
example: "0.6"
|
|
selector:
|
|
number:
|
|
min: 0
|
|
max: 10
|
|
step: 0.01
|
|
mode: box
|
|
tpi_coef_ext:
|
|
name: Coef Ext
|
|
description: Coefficient External
|
|
required: false
|
|
advanced: false
|
|
example: "0.01"
|
|
selector:
|
|
number:
|
|
min: 0
|
|
max: 1
|
|
step: 0.001
|
|
mode: box
|
|
minimal_activation_delay:
|
|
name: Minimal Activation delay
|
|
description: Delay in seconds under which the equipment will not be activated
|
|
required: false
|
|
advanced: true
|
|
example: "10"
|
|
selector:
|
|
number:
|
|
min: 0
|
|
max: 1000
|
|
step: 1
|
|
mode: box
|
|
unit_of_measurement: "seconds"
|
|
minimal_deactivation_delay:
|
|
name: Minimal Deactivation delay
|
|
description: Delay in seconds under which the equipment will be kept active
|
|
required: false
|
|
advanced: true
|
|
example: "10"
|
|
selector:
|
|
number:
|
|
min: 0
|
|
max: 1000
|
|
step: 1
|
|
mode: box
|
|
unit_of_measurement: "seconds"
|
|
tpi_threshold_low:
|
|
name: Low TPI threshold
|
|
description: Threshold in ° under which the TPI algorithm will be on. 0 means no threshold
|
|
required: false
|
|
advanced: false
|
|
example: "0.1"
|
|
selector:
|
|
number:
|
|
min: -10
|
|
max: 10
|
|
step: 0.1
|
|
mode: box
|
|
unit_of_measurement: "°"
|
|
tpi_threshold_high:
|
|
name: High TPI threshold
|
|
description: Threshold in ° above which the TPI algorithm will be off. 0 means no threshold
|
|
required: false
|
|
advanced: false
|
|
example: "0.1"
|
|
selector:
|
|
number:
|
|
min: -10
|
|
max: 10
|
|
step: 0.1
|
|
mode: box
|
|
unit_of_measurement: "°"
|
|
|
|
set_auto_tpi_mode:
|
|
name: Set Auto TPI mode
|
|
description: Enable or disable the Auto TPI learning mode.
|
|
target:
|
|
entity:
|
|
integration: versatile_thermostat
|
|
domain:
|
|
- climate
|
|
fields:
|
|
auto_tpi_mode:
|
|
name: Auto TPI mode
|
|
description: Enable (true) or disable (false) the Auto TPI learning
|
|
required: true
|
|
advanced: false
|
|
default: true
|
|
selector:
|
|
boolean:
|
|
reinitialise:
|
|
name: Reset learning data
|
|
description: Reset all learning data when enabling Auto TPI mode (default is true)
|
|
required: false
|
|
advanced: false
|
|
default: true
|
|
selector:
|
|
boolean:
|
|
allow_kint_boost_on_stagnation:
|
|
name: Allow Kint boost
|
|
description: Allow boosting Kint when temperature stagnates despite demand (default false)
|
|
required: true
|
|
advanced: false
|
|
default: false
|
|
selector:
|
|
boolean:
|
|
allow_kext_compensation_on_overshoot:
|
|
name: Allow Kext compensation
|
|
description: Allow adjusting Kext when temperature overshoots (default false)
|
|
required: true
|
|
advanced: false
|
|
default: false
|
|
selector:
|
|
boolean:
|
|
|
|
|
|
auto_tpi_calibrate_capacity:
|
|
name: Auto Tpi Calibrate Capacity
|
|
description: Calibrate the heating/cooling capacity (in min/°) using linear regression on the entity's history data.
|
|
target:
|
|
entity:
|
|
integration: versatile_thermostat
|
|
domain:
|
|
- climate
|
|
fields:
|
|
start_date:
|
|
name: History from date
|
|
description: Date from which to retrieve history (default is 30 days ago)
|
|
required: false
|
|
advanced: false
|
|
example: "2023-11-01"
|
|
selector:
|
|
date:
|
|
end_date:
|
|
name: History to date
|
|
description: Date until which to retrieve history (default is now)
|
|
required: false
|
|
advanced: false
|
|
example: "2023-12-01"
|
|
selector:
|
|
date:
|
|
min_power_threshold:
|
|
name: Minimum Power Threshold
|
|
description: Minimum power percentage to consider a cycle as saturated (default 95%). Lower values (e.g., 90%) will include more cycles but may be less accurate.
|
|
required: true
|
|
default: 95
|
|
advanced: true
|
|
example: 95
|
|
selector:
|
|
number:
|
|
min: 80
|
|
max: 100
|
|
step: 1
|
|
unit_of_measurement: "%"
|
|
mode: slider
|
|
save_to_config:
|
|
name: Save to Config
|
|
description: Whether to apply the calculated capacity to the entity's configuration
|
|
required: true
|
|
advanced: false
|
|
example: true
|
|
selector:
|
|
boolean:
|
|
|
|
set_timed_preset:
|
|
name: Set Timed Preset
|
|
description: Force a preset for a given duration. After the duration expires, the original preset will be restored.
|
|
target:
|
|
entity:
|
|
integration: versatile_thermostat
|
|
domain:
|
|
- climate
|
|
fields:
|
|
preset:
|
|
name: Preset
|
|
description: The preset to apply temporarily
|
|
required: true
|
|
advanced: false
|
|
example: "boost"
|
|
selector:
|
|
text:
|
|
duration_minutes:
|
|
name: Duration (minutes)
|
|
description: Duration in minutes for which the preset will be active
|
|
required: true
|
|
advanced: false
|
|
example: 30
|
|
default: 30
|
|
selector:
|
|
number:
|
|
min: 1
|
|
max: 1440
|
|
step: 1
|
|
unit_of_measurement: "min"
|
|
mode: box
|
|
|
|
cancel_timed_preset:
|
|
name: Cancel Timed Preset
|
|
description: Cancel any active timed preset and restore the original preset.
|
|
target:
|
|
entity:
|
|
integration: versatile_thermostat
|
|
domain:
|
|
- climate
|
|
|
|
recalibrate_valves:
|
|
name: Recalibrate valves
|
|
description: Recalibrate opening/closing degrees for all valve underlyings of a VTherm (only over_climate_valve).
|
|
target:
|
|
entity:
|
|
integration: versatile_thermostat
|
|
domain:
|
|
- climate
|
|
fields:
|
|
delay_seconds:
|
|
name: Delay seconds
|
|
description: Delay in seconds between open and close step for each valve
|
|
required: true
|
|
example: 5
|
|
default: 60
|
|
selector:
|
|
number:
|
|
min: 30
|
|
max: 300
|
|
|
|
download_logs:
|
|
name: Download logs
|
|
description: Collect and download filtered logs for a VTherm entity.
|
|
target:
|
|
entity:
|
|
integration: versatile_thermostat
|
|
domain:
|
|
- climate
|
|
fields:
|
|
log_level:
|
|
name: Log level
|
|
description: Minimum log level to include
|
|
required: false
|
|
default: "DEBUG"
|
|
selector:
|
|
select:
|
|
options:
|
|
- "DEBUG"
|
|
- "INFO"
|
|
- "WARNING"
|
|
- "ERROR"
|
|
period_start:
|
|
name: Period start
|
|
description: Start of the extraction period (default is 60 minutes ago)
|
|
required: false
|
|
selector:
|
|
datetime:
|
|
period_end:
|
|
name: Period end
|
|
description: End of the extraction period (default is now)
|
|
required: false
|
|
selector:
|
|
datetime:
|