322 lines
15 KiB
Python
322 lines
15 KiB
Python
"""Boilers, heating & water treatment.
|
||
|
||
Data module of the suggested-setups signature catalog — see
|
||
``helpers/signatures/_model.py`` for the direction semantics and the
|
||
method contract (every entry cites and is verified against the
|
||
integration's source; drift-probed weekly)."""
|
||
|
||
from __future__ import annotations
|
||
|
||
from ._model import ConsumableSignature, IntegrationSignature
|
||
from ._shared import HEATING_WATER_PRESSURE_LOW, SOFTENER_SALT_LEVEL
|
||
|
||
SIGNATURES: dict[str, IntegrationSignature] = {
|
||
"vicare": IntegrationSignature(
|
||
name="Viessmann ViCare",
|
||
verified="2026-07-17 (filter) / 2026-07-18 (burner) @ home-assistant/core dev + openviess/PyViCare master",
|
||
source=(
|
||
"home-assistant/core homeassistant/components/vicare/sensor.py "
|
||
"(GLOBAL_SENSORS translation_key 'filter_remaining_hours', UnitOfTime.HOURS, "
|
||
"disabled-by-default; PyViCare ventilation.filter.runtime.remainingHours; "
|
||
"BURNER_SENSORS/COMPRESSOR_SENSORS 'burner_hours'/'compressor_hours', "
|
||
"UnitOfTime.HOURS, TOTAL_INCREASING lifetime → usage_delta)."
|
||
),
|
||
tasks=(
|
||
ConsumableSignature(("filter_remaining_hours",), "Replace Filter", "duration_left"),
|
||
# Boiler/heat-pump service by accumulated operating hours since the
|
||
# last service — the counters are lifetime (no reset), which is
|
||
# exactly what the delta-baseline trigger models.
|
||
ConsumableSignature(
|
||
("burner_hours", "compressor_hours"),
|
||
"Annual Inspection",
|
||
"usage_delta",
|
||
delta_units=2000,
|
||
),
|
||
),
|
||
),
|
||
"bosch": IntegrationSignature(
|
||
name="Bosch/Buderus heating",
|
||
verified="2026-07-18 @ bosch-thermostat/home-assistant-bosch-custom-component master + live RC300 registry",
|
||
source=(
|
||
"bosch-thermostat custom component: sensors are DYNAMIC (named "
|
||
"from the device's XMPP data, sensor/base.py builds names without "
|
||
"a device prefix → entity ids like sensor.system_pressure; no "
|
||
"translation_keys). Key verified against a live Buderus RC300 "
|
||
"registry; matched via the exact-object-id pattern."
|
||
),
|
||
tasks=(
|
||
# Heating-loop pressure: refill water when it drops below 1 bar;
|
||
# topping up raises the value back (auto-resolve).
|
||
ConsumableSignature(("system_pressure",), "Refill Heating Water", "value_below", delta_units=1),
|
||
),
|
||
),
|
||
# ─── Research round 4 (2026-07-19): boiler pressure, HRV filters, ───
|
||
# ─── purifiers, espresso, pet tech, Klipper ─────────────────────────
|
||
"opentherm_gw": IntegrationSignature(
|
||
name="OpenTherm Gateway",
|
||
verified="2026-07-19 @ core/dev opentherm_gw/sensor.py",
|
||
source=(
|
||
"core opentherm_gw: tk 'central_heating_pressure', BAR, MEASUREMENT — generic for EVERY OpenTherm-connected boiler."
|
||
),
|
||
tasks=(ConsumableSignature(("central_heating_pressure",), "Refill Heating Water", "value_below", delta_units=1),),
|
||
),
|
||
"plugwise": IntegrationSignature(
|
||
name="Plugwise (Anna/Adam)",
|
||
verified="2026-07-19 @ core/dev plugwise/sensor.py",
|
||
source="core plugwise: tk 'water_pressure', BAR, MEASUREMENT (boiler loop).",
|
||
tasks=(HEATING_WATER_PRESSURE_LOW,),
|
||
),
|
||
"incomfort": IntegrationSignature(
|
||
name="Intergas InComfort",
|
||
verified="2026-07-19 @ core/dev incomfort/sensor.py",
|
||
source=(
|
||
"core incomfort: key 'cv_pressure', BAR, MEASUREMENT. NOTE: "
|
||
"entity_registry_enabled_default=False — the suggestion appears "
|
||
"once the user enables the sensor."
|
||
),
|
||
tasks=(ConsumableSignature(("cv_pressure",), "Refill Heating Water", "value_below", delta_units=1),),
|
||
),
|
||
"atag": IntegrationSignature(
|
||
name="ATAG One",
|
||
verified="2026-07-19 @ core/dev atag/sensor.py",
|
||
source=(
|
||
"core atag: legacy name-based sensors ('CH Water Pressure' → "
|
||
"object id ch_water_pressure), BAR — matched via suffix or the "
|
||
"exact-object-id pattern."
|
||
),
|
||
tasks=(ConsumableSignature(("ch_water_pressure",), "Refill Heating Water", "value_below", delta_units=1),),
|
||
),
|
||
"bwt_perla": IntegrationSignature(
|
||
name="BWT Perla",
|
||
verified="2026-07-19 @ dkarv/ha-bwt-perla main sensor.py (HACS default)",
|
||
source=(
|
||
"HACS bwt_perla (dkarv): tk 'regenerativ_level' (salt reserve, "
|
||
"PERCENTAGE) and tk 'regenerativ_days' (days of salt left, "
|
||
"UnitOfTime.DAYS) — refilling raises both (auto-resolve)."
|
||
),
|
||
tasks=(
|
||
ConsumableSignature(("regenerativ_level",), "Refill Softener Salt", "percent_left"),
|
||
ConsumableSignature(("regenerativ_days",), "Refill Softener Salt", "duration_left", below_hours=168),
|
||
),
|
||
),
|
||
"ecowater_softener": IntegrationSignature(
|
||
name="EcoWater softener",
|
||
verified="2026-07-19 @ barleybobs/homeassistant-ecowater-softener master (HACS default)",
|
||
source=(
|
||
"HACS ecowater_softener (barleybobs): key 'salt_level_percentage' "
|
||
"(PERCENTAGE) and key 'out_of_salt_days' (days) — name-style "
|
||
"entities, suffix-matched."
|
||
),
|
||
tasks=(
|
||
ConsumableSignature(("salt_level_percentage",), "Refill Softener Salt", "percent_left"),
|
||
ConsumableSignature(("out_of_salt_days",), "Refill Softener Salt", "duration_left", below_hours=168),
|
||
),
|
||
),
|
||
"wolflink": IntegrationSignature(
|
||
name="Wolf SmartSet",
|
||
verified="2026-07-19 @ core/dev wolflink/sensor.py",
|
||
source="core wolflink: key 'pressure', BAR (heating loop).",
|
||
tasks=(ConsumableSignature(("pressure",), "Refill Heating Water", "value_below", delta_units=1),),
|
||
),
|
||
"palazzetti": IntegrationSignature(
|
||
name="Palazzetti pellet stove",
|
||
verified="2026-07-19 @ core/dev palazzetti/sensor.py",
|
||
source=(
|
||
"core palazzetti: tk 'pellet_quantity' (KILOGRAMS consumed, "
|
||
"cumulative) -> usage_delta; ash-pan cadence ~100 kg of pellets "
|
||
"(editorial: roughly weekly in season; manuals prescribe "
|
||
"calendar-based cleaning). 'pellet_level' is a CM tank gauge — "
|
||
"inventory, not wear; skipped."
|
||
),
|
||
tasks=(ConsumableSignature(("pellet_quantity",), "Empty Ash Pan", "usage_delta", delta_units=100),),
|
||
),
|
||
"mypyllant": IntegrationSignature(
|
||
name="Vaillant (myVAILLANT)",
|
||
verified="2026-07-19 @ signalkraft/mypyllant-component main sensor.py",
|
||
source=(
|
||
"HACS mypyllant: SystemWaterPressureSensor (name '... System "
|
||
"Water Pressure' -> suffix system_water_pressure) and the "
|
||
"device-level operational-data variant (suffix water_pressure), "
|
||
"both BAR — matched any-low."
|
||
),
|
||
tasks=(
|
||
ConsumableSignature(
|
||
("system_water_pressure", "water_pressure"),
|
||
"Refill Heating Water",
|
||
"value_below",
|
||
delta_units=1,
|
||
),
|
||
),
|
||
),
|
||
"grohe_smarthome": IntegrationSignature(
|
||
name="Grohe Blue",
|
||
verified="2026-07-19 @ flo-schilli/ha-grohe_smarthome main (HACS default)",
|
||
source=(
|
||
"HACS grohe_smarthome, yaml-driven name-derived entities "
|
||
"(config/config.yaml, GroheBlueHome/GroheBlueProf): 'Remaining "
|
||
"Filter' (%) and 'Remaining CO2' (%) — reset by the device's own "
|
||
"filter/CO2 reset commands. The sibling 'Remaining Filter (App)' "
|
||
"slugs to _remaining_filter_app and cannot clash with the exact "
|
||
"_remaining_filter suffix."
|
||
),
|
||
tasks=(
|
||
ConsumableSignature(("remaining_filter",), "Replace Water Filter", "percent_left"),
|
||
ConsumableSignature(("remaining_co2",), "Replace CO2 Bottle", "percent_left"),
|
||
),
|
||
),
|
||
"iqua_softener": IntegrationSignature(
|
||
name="iQua softener",
|
||
verified="2026-07-20 @ mutilator/homeassistant-iqua-softener master sensor.py (HACS default)",
|
||
source=(
|
||
"HACS iqua_softener: 'Salt level' (PERCENTAGE, name-style -> "
|
||
"suffix _salt_level). 'Out of salt estimated day' is a DATE "
|
||
"sensor - parked for the date direction."
|
||
),
|
||
tasks=(SOFTENER_SALT_LEVEL,),
|
||
),
|
||
"fumis": IntegrationSignature(
|
||
name="Fumis (pellet stoves)",
|
||
verified="2026-07-20 @ home-assistant/core dev",
|
||
source=(
|
||
"core fumis: tk 'time_to_service' (DURATION, HOURS remaining) — "
|
||
"the controller's own service countdown for Fumis-driven pellet "
|
||
"stoves/boilers."
|
||
),
|
||
tasks=(ConsumableSignature(("time_to_service",), "Annual Service", "duration_left"),),
|
||
),
|
||
"rehlko": IntegrationSignature(
|
||
name="Rehlko / Kohler generators",
|
||
verified="2026-07-20 @ home-assistant/core dev",
|
||
source=(
|
||
"core rehlko: tk 'runtime_since_last_maintenance' (HOURS since "
|
||
"the last maintenance, resets when maintenance is recorded) → "
|
||
"usage_above at 100 h — Kohler's oil-change interval (every "
|
||
"100 run-hours or annually). An 'oil_pressure' problem binary "
|
||
"also exists (adoption path)."
|
||
),
|
||
tasks=(ConsumableSignature(("runtime_since_last_maintenance",), "Oil Service", "usage_above", above_hours=100),),
|
||
),
|
||
"aquacell": IntegrationSignature(
|
||
name="AquaCell softener",
|
||
verified="2026-07-20 @ home-assistant/core dev",
|
||
source=(
|
||
"core aquacell: tk 'salt_left_side_percentage' and "
|
||
"'salt_right_side_percentage' (PERCENTAGE) — dual salt tanks, "
|
||
"matched any-low."
|
||
),
|
||
tasks=(
|
||
ConsumableSignature(
|
||
("salt_left_side_percentage", "salt_right_side_percentage"),
|
||
"Refill Softener Salt",
|
||
"percent_left",
|
||
),
|
||
),
|
||
),
|
||
# ─── Round 14 (2026-09-25): boiler pressure, softener salt, ─────────
|
||
# ─── generator engine hours ──────────────────────────────────────────
|
||
"de_dietrich": IntegrationSignature(
|
||
name="De Dietrich (Diematic)",
|
||
verified="2026-09-25 @ home-assistant/core dev",
|
||
source=(
|
||
"core de_dietrich (new on dev = 2026.10, Diematic Modbus): tk "
|
||
"'water_pressure', UnitOfPressure.BAR, MEASUREMENT (boiler loop)."
|
||
),
|
||
tasks=(HEATING_WATER_PRESSURE_LOW,),
|
||
),
|
||
"remeha_home": IntegrationSignature(
|
||
name="Remeha Home",
|
||
verified="2026-09-25 @ msvisser/remeha_home main",
|
||
source=(
|
||
"HACS remeha_home const.py APPLIANCE_SENSOR_TYPES: key "
|
||
"'waterPressure', name 'Water Pressure' (BAR, MEASUREMENT; "
|
||
"has_entity_name without translation_key → suffix "
|
||
"_water_pressure)."
|
||
),
|
||
tasks=(HEATING_WATER_PRESSURE_LOW,),
|
||
),
|
||
"syr_connect": IntegrationSignature(
|
||
name="SYR Connect (softeners)",
|
||
verified="2026-09-25 @ alexhass/syr_connect main",
|
||
source=(
|
||
"HACS syr_connect sensor.py sets _attr_translation_key = "
|
||
"sensor_key.lower() → tk 'getss1' ('Salt container stock 1'; "
|
||
"const.py: getSS1 = salt supply of container 1 in "
|
||
"UnitOfTime.WEEKS, MEASUREMENT, no device class). Weeks are not a "
|
||
"unit the duration conversion knows, so the duty is a "
|
||
"value_below in the entity's own unit: below 2 weeks (= 336 h). "
|
||
"getSS2/getSS3 (extra containers, disabled by default, absent on "
|
||
"most devices) are left out."
|
||
),
|
||
tasks=(ConsumableSignature(("getss1",), "Refill Softener Salt", "value_below", delta_units=2),),
|
||
),
|
||
"salt_sentry": IntegrationSignature(
|
||
name="Salt Sentry",
|
||
verified="2026-09-25 @ Lemcke-solutions/Salt-sentry-ha-integration main",
|
||
source=(
|
||
"HACS salt_sentry sensor.py SaltPercentageSensor: tk "
|
||
"'salt_level', '%' = (empty − distance) / (empty − full) × 100 — "
|
||
"the salt REMAINING in the brine tank (ultrasonic level sensor)."
|
||
),
|
||
tasks=(SOFTENER_SALT_LEVEL,),
|
||
),
|
||
"unique_waterontharder": IntegrationSignature(
|
||
name="Unique Waterontharder",
|
||
verified="2026-09-25 @ mirkin-pixel/ha-unique-waterontharders main",
|
||
source=(
|
||
"HACS unique_waterontharder sensor.py: tk 'salt_level', "
|
||
"PERCENTAGE, MEASUREMENT — the cloud API's 'zout_niveau' (salt "
|
||
"level)."
|
||
),
|
||
tasks=(SOFTENER_SALT_LEVEL,),
|
||
),
|
||
"bwt_aqa_perla_ble": IntegrationSignature(
|
||
name="BWT AQA Perla (BLE)",
|
||
verified="2026-09-25 @ Micka41/bwt-aqa-perla-ble main",
|
||
source=(
|
||
"HACS bwt_aqa_perla_ble sensor.py: tk 'salt_pct', PERCENTAGE, "
|
||
"MEASUREMENT — coordinator.py decodes it as remaining salt × 100 "
|
||
"// tank capacity ('qte_sel_restant'). A 'salt_alarm' problem "
|
||
"binary also exists (adoption path)."
|
||
),
|
||
tasks=(ConsumableSignature(("salt_pct",), "Refill Softener Salt", "percent_left"),),
|
||
),
|
||
"generac": IntegrationSignature(
|
||
name="Generac (Mobile Link)",
|
||
verified="2026-09-25 @ binarydev/ha-generac main",
|
||
source=(
|
||
"HACS generac sensor.py RunTimeSensor: name sensor_name(self, "
|
||
"'run_time') = 'generac_<device_id>_run_time' → suffix _run_time, "
|
||
"DURATION, 'h'; value = apparatus property type 71, which the "
|
||
"Mobile Link API labels 'Engine Hours' (payload quoted in issue "
|
||
"#202) — the LIFETIME engine-hours counter → usage_delta every "
|
||
"200 h (Generac air-cooled home-standby schedule: oil and filter "
|
||
"every 200 h or 2 years). The pjordanandrsn fork shares the "
|
||
"domain and the same property-71 sensor."
|
||
),
|
||
tasks=(ConsumableSignature(("run_time",), "Oil Service", "usage_delta", delta_units=200),),
|
||
),
|
||
"energytrak": IntegrationSignature(
|
||
name="EnergyTrak (generators)",
|
||
verified="2026-09-25 @ brentb2529/ha-energytrak main",
|
||
source=(
|
||
"HACS energytrak sensor.py: tk 'engine_hours' (DURATION, HOURS, "
|
||
"TOTAL_INCREASING; normalize.py: 'a monotonic counter that is "
|
||
"always > 0 on an installed unit') — LIFETIME → usage_delta every "
|
||
"200 h (standby-generator oil cadence, as for Generac)."
|
||
),
|
||
tasks=(ConsumableSignature(("engine_hours",), "Oil Service", "usage_delta", delta_units=200),),
|
||
),
|
||
"himoinsa_c4lan": IntegrationSignature(
|
||
name="Himoinsa C4LAN generators",
|
||
verified="2026-09-25 @ spiri439/himoinsa-c4lan main",
|
||
source=(
|
||
"HACS himoinsa_c4lan sensor.py: key 'engine_hours', name 'Engine "
|
||
"hours' (Modbus input register 42 = total engine hours per "
|
||
"const.py; HOURS, DURATION, TOTAL_INCREASING; has_entity_name "
|
||
"without translation_key → suffix _engine_hours) — LIFETIME → "
|
||
"usage_delta every 250 h (typical diesel-genset oil interval)."
|
||
),
|
||
tasks=(ConsumableSignature(("engine_hours",), "Oil Service", "usage_delta", delta_units=250),),
|
||
),
|
||
}
|