Files

1.5 KiB

Downstairs Bathroom Light - Debug Session (2026-07-24)

Issue

Motion sensor triggers but bathroom light has a 20-30 second delay turning on.

Key Entities

  • automation.downstairs_bathroom_light_contro — automation (mode: restart, working correctly)
  • binary_sensor.downstairs_bathroom_occupancy — Third Reality Zigbee motion sensor (Z2M)
  • switch.downstairs_bathroom_switch — TP-Link HS200 (exposed via Homebridge)
  • light.bathroom_light — TP-Link HS220 dimmer (separate device, NOT controlled by automation)

Findings

  1. Automation logic is correct — triggers on occupancy on/off, 30-min timeout, mode restart
  2. Automation IS firing and switch IS turning on (confirmed via history)
  3. The delay is between automation trigger and switch responding — suggests Homebridge communication delay
  4. No other HA automations reference this switch
  5. User confirmed no HomeKit/TP-Link app automations interfering
  6. User tried restarting Homebridge — delay persisted
  7. User was about to restart entire HA server to test

Resolution (2026-07-23)

Full HA server restart resolved the issue. Post-reboot trigger-to-action times are all under 0.5s. The delay was caused by a stale Homebridge WebSocket connection to the TP-Link HS200.

Next Steps If Issue Recurs

  • Check Homebridge logs for TP-Link communication errors
  • Consider switching automation to control light.bathroom_light (HS220) directly if TP-Link integration is available
  • Check if Homebridge add-on needs update